Argo TT UPS - On line double conversion UPS




Uninterruptible
power supply
On line double conversion





    • 3-phase input/output.
    • Double conversion transformerless.
    • Compact size and light weight.

    • PFC circuit: high Power Factor and low harmonic distortion of input current, (clean version).

    • Microprocessor control.
    • Self diagnose.
    • Multilanguage LDC Display allows a comprehensive UPS management (setting, measures).

    • Designed for any kind of application.
    • Wide input voltage range.
    • Sine-wave output regulated voltage.
    • Efficiency increase.
    • Static and Service By-Pass.
    • Automatic and manual battery test.
    • Autonomy extension capability.
    • Parallel redundant architecture (up to 8 units).
    • Low acoustic noise, fans speed regulation.
    • N° 2 RS232 serial ports, EPO and contacts port.
    • Remote display panel.
    • Smart Active for energy saving.
    • Wheels equipped.
    • CD Shutdown software, for most common Operating Systems.
    • SNMP and modem capability.

Technical characteristics
SYSTEM 3-phase output MODELS
Nominal Capacity [KVA] 10 15 20 30
Input 3-phase
Remote signals Remote signals
Remote commands EPO and by-pass
Communication 2 x RS232/C
Environment temperature 0 - 40° C
Humidity 95% (non condensing)
Cooling Forced air
Acoustic noise <56 dba
Protection degree IP20
Efficiency > 92%
In compliance with Safety EN 50091-1-1 ,EMC EN 50091-2 Lev.A
Dimensions WxDxH [mm] 450x750x1200
Weight UPS +
standard battery [Kg.]
95+90 100+135 115+135 120+190
RECTIFIER INPUT
Nominal voltage 400V 3-phase + N
Voltage rangee ± 20%
Frequency [Hz] 45 ÷ 65
Power Factor 0.95
Current distortion <27% (<9% clean version)
BATTERY
Type Sealed lead acid maintenance free
Number / V / Ah 32/12/7 48/12/7 48/12/12
Recharging time [h] 8
Autonomy full load [min.] 8 8 7 6
INVERTER OUTPUT
Power rating [KVA] 10 15 20 30
Active power [kW] 8 12 16 24
Phase N. 3+N
3-phase nominal voltage 400V+N
Voltage adjusting range 346 ÷ 422V
Crest Factor [Ipeak/Irms] 3:1
Wave shape Sinusoidal
Distortion with linear load <2%
Static stability <1%
Dynamic stability <5% in 10 ms
Frequency [Hz] 50/60 selectable
Overload 125/150% nominal current 10’ / 1’
BY-PASS
Nominal voltage 400V
Phase N. 3+N
Admitted voltage range ± 15% (selectable from ± 5% to ± 25%)
Nominal frequency [Hz] 50 / 60
Admitted frequency range ±2% (selectable from ± 1% to ± 5%)